With enhanced particle charging technology, PNED C-Ultra offers even higher sensitivity for smoke detection which is ideal for applications with high requirements for cleanliness such as cleanroom, semiconductor manufacturing and bioengineering laboratory.  

 

Relying on extreme high sensitivity, PNED C-Ultra realises extra function for monitoring contamination levels by applying mathematical analysis on the sampling airflow. The upper boundary of Class 6, Class 7 and Class 8 cleanroom cleanliness can be clearly identified by PNED C-Ultra in accordance with ISO 14644 standards, providing a reference measurement for cleanroom cleanliness monitoring. 

Power

Supply voltage

Sensitivity 

Dimension

Weight

Aera coverage

Operating conditions

Airflow

Pipe length

No. of holes

IP rating

Pipe specifications

Cables

​Threshold settings

C-Ultra-P1

C-Ultra-P4

2100W

24VDC

 

60mm×60mm×60mm

4kg

​1000 square meters

Ambient:

Humidity:

Sampled air:

2.83L/mins

100m

100

IP40

 

Inner radius:    

Outer radius:

10mm diameters

 

Alert:

Action:

Fire 1:

Fire 2:

2100W

24VDC

60mm×60mm×60mm

4kg

​1000 square meters

Ambient:

Humidity:

Sampled air:

2.83L/mins

100m

100

IP40

 

Inner radius:    

Outer radius:

10mm diameters

 

Alert:

Action:

Fire 1:

Fire 2:

  • Cleanroom

  • ​Semiconductor manufacturing

  • Bioengineering laboratory

  • Hospital operating room

  • Electronic factory

  • Unique detecting mechanism obtains extraordinary performance for detecting smoke particles at the pyrolysis stage of the incipient fire;

  • The exclusive contamination monitoring system offers three levels of monitoring, including Class 6, Class 7 and Class 8, complying with ISO 14644 cleanroom cleanliness standards;

  • Dual-electrodes collects both micro smoke particles and macro smoke particles for better detection performance and fewer false alarm;

  • Ultra-sonic airflow monitoring system ensures stable sampling airflow;

  • The Embedded HPFA filter box provides long term filtration for up to 10 years;

  • Automatic self-cleaning systems reduce maintenance cost and frequency;

  • On-field inspection for a quick check of potential fire threats is available via camera (optional);

  • Exclusive RS485 network deliveries higher baud rate than regular RS485 network and fully compatible with pre-existing RS485 network;

  • Two sampling configurations are available for all range of applications: Single-pipeline and Four-pipeline configurations;

  • Four alarm levels.

Related products

PNED L-P1

Laser-based ASD with single pipeline perfect for long-range applications

PNED L-P4

Laser-based ASD with four parallel pipelines suitable for open space applications

PNED monitoring software

Exclusive software platform for real-time system monitoring. 

C-Ultra P1 Particle charging Aspirating smoke detector 

C-Ultra P4 Particle charging Aspirating smoke detector 

blackbackground2_edited.jpg
Positive corona charger

Ions impact and attachment in the mixing chamber allow smoke particles down to 20nm to be charged efficiently.

Better ultra-small particles detection

Mixing chamber

A positive corona charger maximises positive ions concentration around the discharge needle, enhancing the charger's efficiency in a great manner.

Charge collector

Dual-electrodes design for charge collection obtains excellent collecting performance for both nanoparticles and microparticles.

​Massive data collection and smoke characteristic analysation

Charged smoke particle diffusion in the electric field allows smoke particles down to 20nm to be detected at the pyroylsis stage of fire.

Real-time photograph 

The real-time image can be transmitted via the local network, offering an extra option for on-site inspection.

180° rotation angle captures more information. Flashing light offers better image quality in a dark environment.

Allow pre-check before taking actions

Exclusive RS485 transmission/ Repeaters

On the basis of traditional RS485 data communication, the R&D team of Partirx has developed a new RS485-based synchronous communication technology to solve the problem of on-site image transmission, so that each device can quickly upload on-site pictures to the main control room at a rate up to 0.962 MHz.

Enhanced data transmission rate and great compatibility

The advantage of using RS485 transmission is that it has a wide range of compatibility and can be perfectly connected with the existing RS485 communication network without any modification. 

bottom of page